The Operator Edition permits at-a-glance monitoring of network status by mapping the network with its complete hierarchical structure and topology. HiVision and HiOPC enable secure and easy configuration as well as the monitoring of industrial network components in real time.


Industrial HiVision - operator Editon
Network management for monitoring of industrial networks with up to 25 nodes (IP-addresses). Node extension to increase the amount of supervised nodes, licenses can be combined. Additional licenses on request.
Topology recognition Topology recognition is based on LLDP (Link Layer Discovery Protocol, IEEE802.1AB) provided by the switches, WLAN and terminal recognition Monitoring map-representation, device state, link and connection state (cable break, utilization), powersupply and fan state, ..., ICMP (Ping) and SNMP availability MAC/IP address assignment
Modules and components MACH, MICE, RS2,Foundry Networks FastIron Serie, EAGLE,RS20/30, MICE20/30, OCTOPUS 16/24, LION, GigaLION, BAT54 Rail, SNMP capable switches, any ICMP(Ping) capable device (PLC, decentral IO module, PCs, ...)lisation (from release 3.0)
OPC Server Map, device and connection states as well as device propertiescould be used inside SCADA systems via the OPC Data Access 2.0/3.0 interface ActiveX Control Map-representations could be reused inside SCADA systems via an ActiveX control.
Supported protocols HiDiscovery, ICMP (Ping), SNMPv1, SNMPv2c, SNMPv3, OPC DA 2.0/3.0.